<b>°Ë»ö »ó¼¼º¸±â : [¼öÁú]</b> - Transmission Flow Cells - FC 81
Notice

ÆǸŰ³½Ã!
TurboVap® LV • II • EH
All New & All Better!.

new TurboVap µÑ·¯º¸±â

• Gas Vortex Shearing Technology
• End-Point °¨Áö ¼¾¼­
• Multi Rack: ¿©·¯ Å©±â Tube ¼ö¿ë
• °¡½º ¸Å´ÏÆúµå Á¶Àý ±³Ã¼ °¡´É
• ´Ù¾çÇÑ Á¾·á¸ðµå: Manual Time Endpoint Endpoint+Time Method

• 7" Ä÷¯ ÅÍÄ¡½ºÅ©¸° Á¦¾îÆÇ ³»Àå
• 4¸éÀÌ Åõ¸íÇÑ À¯¸® ¼öÁ¶
• Àü¸é ¹è¼ö Æ÷Æ®
• ¼öÁ¶ Á¶¸í°ú °æº¸À½À¸·Î Á¾·á ¾Ë¸²
• ÀýÀü¸ðµå¿Í ÀÚµ¿ ¿þÀÌÅ©¾÷

     
 
Home > Product > ¼öÁú > Biofilm > Flow Cell

Á¦ Ç° ¸í : Transmission Flow Cells - FC 81
Á¦ Á¶ »ç : BioSurface
Á¦Ç°ÄÚµå : FC81
 
   
»ó¼¼¼³¸í


FC 81 Transmission Flow Cells

The BST Model FC 81 Transmission Flow Cell is a single channel transmission flow cell that uses a standard microscope coverslip and microscope glass slide as viewing windows. The flow chamber on the FC 81 Flow Cell is made from either clear polycarbonate plastic or black anodized aluminum. Both material types are fully autoclavable and reuseable. Anodized aluminum provides a more rugged material to last through numerous autoclave cycles (all plastics, including polycarbonate, will deteriorate with repeated autoclave cycles). The flow chamber on the FC 81 is approximately 2.0¡± (50 mm) long by 0.5¡± (13 mm) wide by 0.10¡± (2.35 mm) deep. The flow chamber can also be used to insert irregularly shaped materials, such as sutures, pieces of cather, sand, etc. for imaging biofilm growth.

The FC 81 Transmission Flow Cell is constructed in a sandwich of aluminum compression plates, silicone rubber gaskets, and the polycarbonate or anodized aluminum flow channel. The FC 81 Flow Cell has integrated barbed fittings that acco- modate size 16 (3 mm ID) tubing. The BST FC 81 Flow Cell uses commercially available microscope coverslips (60 x 24 mm; no. 2) and microscope slides (25 x 75 x 1 mm) as viewing windows. The use of cover slips as viewing windows combines high quality optical glass, thin dimensions (increases working focal depth into the chamber) and low cost. These viewing windows can be removed and replaced easily between experiments.

The FC 81 Flow Cell is provided with a standard, platform-stage microscope mount. Alternate mounting plates are available to mount the flow cell into a 96-well microtiter plate holder that are common on many upright and inverted microscopes. The stage mount allows direct attachment to upright and inverted microscope stages. The FC 81 Transmission Flow Cell allows biofilm imaging using transmitted, epi-fluorescence, or confocal microscopy.

 



 

Map
Anyang Mega Valley RM 819, 268, Hagui-ro, Dongan-gu, Anyang-si, Gyeonggi-do, Republic of Korea 14056
¡¼Tel¡½+82-(0)2-571-3444 ¡¼Fax¡½+82-(0)2-571-4877